Starting Manual Continuity Check
Applies to: Tmedia 3.0, 3.2, 3.3
Note: the option might not be available if the resources required for the test (tone generation and detection) are not available.1- Select SS7->ISUP from the navigation panel
2- Click the Status tab and click on the appropriate ISUP Stack
3- Click the Interfaces tab and select the appropriate ISUP Interface
4- Click the Circuit Groups tab and select the appropriate Circuit Group
If you want to start a continuity check on all circuits of a circuit group:
Select Yes forStart continuity check and click on Apply states
Click Now to refresh the status and see the result of the test. Some of the following stats should be modified:
Total ccr success cnt
Total ccr fail cnt
Last ccr unknown cnt
Last ccr in progress cnt
Last ccr success cnt
Last ccr fail cnt
Last ccr error cnt
If you want to start a continuity check on a specific circuit:
Click on the Circuits tab and select the circuit in the Cic column.
Select Yes forStart continuity check and click on Apply states
Click on Now to refresh the status and see the result of the test. Some of the following stats should be modified:
Nb outgoing ccr success
Nb outgoing ccr fail
Last ccr result
Last updated
Was this helpful?